Home Services Support About infoMonitors About FSEC infoMonitors.com
 
Data Plots
Help
 
Quick Date:


Start Date:


End Date:


Summary Report
Indoor T & RH
Outdoor T & RH
HVAC Performance
Electric End-uses
Natural Gas Use
DHW Performance
AC Scatterplot


Select
"cp1 database

As part of the U.S. DOE Building America program, FSEC and CPS Energy are evaluating the performance of three homes in San Antonio, Texas with identical ~2,000 ft2 floor plans and orientation. One home built to builder standard practice serves as the control (CP1), while the other homes (CP2 & CP3) demonstrate high performance features.

Control Home (CP1) Features:
- 86 HERS Index
- Standard vented attic (R38)
- Frame walls insulated to R-13
- Single pane, clear glass, metal windows
- SEER 14 air conditioner and 80% gas furnace
- Standard gas tank water heater (EF 0.58)
- All other appliances are electric

Feb 08 2010, 00:15 -To- Feb 09 2010, 00:00 EST

Electricity Usage

kWh

KBtu's
Condenser unit 0.0 0.0
Air Handler 2.2 7.6
Range Top 0.9 2.9
Oven 1.9 6.4
Clothes Dryer 1.7 5.7
Total House 17.8 60.8

Interior Conditions

Average

Min/Max
Thermostat Temp (deg.F) 71.6 71.1/ 72.8
Thermostat Humidity (%RH) 48.2 43.0/ 55.1
Vented Attic Temp (deg.F) 63.2 50.0/ 84.3
Vented Attic Humidity (%RH) 67.1 46.5/ 78.2
Water Heater Inlet (deg.F) 64.3 60.4/ 69.7
Water Heater Outlet (deg.F) 117.1 91.5/ 129.2

Hot Water Flow

Tot/Avg

Min/Max
Tank Water Heater - Tot Gal 79.8 0.0/ 15.2
Tank Water Heater - Avg GPM 0.9 0.2/ 2.7

Natural Gas Usage

CuFt

Total House 159.5
Furnace (estim) 130.1
Tank Water Heater (estim) 29.4

Energy Usage

KWhrs or Cuft

KBtu's
Total House Gas (cuft) 159.5 162.7
House Total Power (KWhrs) 17.8 60.8
Furnace Gas Use (cuft) 130.1 132.7
A/C Compressor Power (KWhrs) 0.0 0.0
A/C Air Handler Power (KWhrs) 2.2 7.6
Electric Range Power (KWhrs) 0.9 2.9
Electric Oven Power (KWhrs) 1.9 6.4
Electric Dryer Energy (KWhrs) 1.7 5.7
e-mail us