Home Services Support About infoMonitors About FSEC InfoMonitors.com
 
Data Plots
Help
 
Quick Date:


Start Date:


End Date:


Summary Report
Indoor T & RH
HVAC Performance
Electric End-uses
Ambient T & RH
Hot Water Heater
AC Scatter Plot
WH Temp & Flow
Hot Water Temps
Duct Moisture

View CHA
data with:

Database-CHA, Central Florida Frame House (Cocoa, FL)

Pre-Retrofit Features:
- Built 1992
- HERS = 101
- Unvented attic
- R19 attic batts
- White metal roof (in 2005)
- Frame walls insulated to R-11
- Single pane, clear windows, Low-E Double Pane Skylights
- Original SEER10 heat pump
- Solar Water Heater, elec. backup (in 1999)
---(4X10 Collector, 80gal Tank with diff. controller)
- All electric appliances

Jul 23 2014, 00:15 -To- Jul 24 2014, 00:00 EST

Electricity Usage

kWh

Compressor Unit 14.6
Air Handler 2.0
Hot Water 1.7
Total House 42.5

Interior Conditions

Avg/Tot

Min/Max
Thermostat Temp (deg.F) 78.8 77.6/ 79.6
Thermostat Humidity (%RH) 49.8 45.6/ 55.9
AC Supply Temp (deg.F) 67.2 53.3/ 80.2
AC Condensate (mL) 4055.0 0.0/ 148.0

Attic Conditions

Average

Min/Max
Mid Attic Temp (deg.F) 86.0 71.7/ 103.1
High Attic Temp (deg.F) 89.5 74.3/ 107.5
Low Attic Temp (deg.F) 86.9 72.7/ 103.6
High Attic Humidity (%RH) 51.0 43.7/ 59.3
Low Attic Humidity (%RH) 54.3 49.5/ 59.6

Duct Conditions

Average

Min/Max
SupplyPlenum Moisture (mV) 459.1 353.9/ 584.3
SE BR Side Moisture (mV) 782.0 658.3/ 900.0
SE BR Bottom Moisture (mV) 1076.7 962.0/ 1376.0
SE Bdrm Side Temp (deg.F) 77.4 64.2/ 90.1
SE Bdrm Bottom Temp (deg.F) 73.4 63.7/ 80.4

Hot Water Data

Avg/Tot

Min/Max
Hall Hot Shower Temp (deg.F) 2.8 1.1/ 13.1
WH Inlet Temp (deg.F) 86.2 78.9/ 99.5
WH Outlet Temp (deg.F) 117.2 105.0/ 132.5
Hot Water Flow (Gal) 61.3 0.0/ 13.2
Hot Water Btu's Output 22352.0
Hot Water Btu's Input 5873.2
W/H Period Efficiency 3.81

Ambient Conditions

Average

Min/Max
Avg Temperature (degF) 82.2 73.0/ 92.2
Avg Relative Humidity (%) 64.0 50.8/ 91.0
e-mail us