Home Services Support About infoMonitors About FSEC infoMonitors.com
 
Data Plots
Help
Data available from July 25, 2001 to
August 2, 2002
 
Quick Date:


Start Date:


End Date:


Summary Report
Heating Energy
Cooling Energy
DHW Energy
House Total Energy
Inside Conditions
Outside Temp & RH
Sun & Wind



NCATU Side-by-Side Study of HUD Code Homes

Specifications of Standard and Energy Construction

Characteristic

Standard Home

Energy Home

Floor Insulation

R-11

R-13

Wall Insulation

R-11

R-22

Ceiling Insulation

R-20

R-33

Windows

Single Pane with Storm

Low-E Thermopane

Exterior Doors

Storm Door on Front

Storm Door on All

Marriage Wall Seal

Fiberglass Pad

Sof-Seal Gasket

Heating System

Electric Resistance

Heat Pump HSPF 7.5

Cooling System

Central Air Conditioning SEER 10

Central Air Conditioning SEER 12

Water Heater

Electric Water Heater

Heliodyne Solar Water Heater

Duct Joints

Industry Standard

Sealed with Mastic

Duct Leakage

CFM25out = 110

CFM25out = 64

House Leakage

ACH50 = 8

ACH50 = 8

Performance of side-by-side manufactured homes on the North Carolina A&T State University campus in Greensboro, NC, a Building America Industrialized Housing Partnership test site. Click here for details.


Side-by-Side Manufacutred Home Comparison
Summary Report
Aug 01 2002, 00:15 -To- Aug 02 2002, 00:00 EST

Total Energy Use (KWh)


Base House Total Power 68.3
Energy House Total Power 41.7

Equipment Energy Use


Base House Space Conditioning Power 42.1
Energy House Space Conditioning Power 24.9
Base House Water Heating Power 8.1
Energy House Water Heating Power 2.0

Indoor Conditions

Avg

Min/Max
Base House Temp (F) 73.8 73.1/ 74.8
Energy House Temp (F) 73.9 73.3/ 74.7
Base House RH (%) 42.9 40.8/ 46.4
Energy House RH (%) 45.1 43.5/ 48.4

Ambient Conditions

Avg

Min/Max
Outside Temp (F) 85.4 74.1/ 99.4
Outside RH (%) 51.6 29.0/ 77.0
e-mail us