Data available from July 25, 2001 to August 2, 2002 |
| |
|
|
|
|
|
|
|
NCATU Side-by-Side Study of HUD Code Homes
Specifications of Standard and Energy Construction
|
Characteristic
|
Standard Home
|
Energy Home
|
Floor Insulation
|
R-11
|
R-13
|
Wall Insulation
|
R-11
|
R-22
|
Ceiling Insulation
|
R-20
|
R-33
|
Windows
|
Single Pane with Storm
|
Low-E Thermopane
|
Exterior Doors
|
Storm Door on Front
|
Storm Door on All
|
Marriage Wall Seal
|
Fiberglass Pad
|
Sof-Seal Gasket
|
Heating System
|
Electric Resistance
|
Heat Pump HSPF 7.5
|
Cooling System
|
Central Air Conditioning SEER 10
|
Central Air Conditioning SEER 12
|
Water Heater
|
Electric Water Heater
|
Heliodyne Solar Water Heater
|
Duct Joints
|
Industry Standard
|
Sealed with Mastic
|
Duct Leakage
|
CFM25out = 110
|
CFM25out = 64
|
House Leakage
|
ACH50 = 8
|
ACH50 = 8
|
Performance of side-by-side manufactured homes on the North Carolina A&T State University campus in Greensboro, NC,
a Building America Industrialized Housing Partnership test site.
Click here for details.
|
Side-by-Side Manufacutred Home Comparison
Summary Report
Aug 01 2002, 00:15 -To- Aug 02 2002, 00:00 EST |
Total Energy Use (KWh) |
|
|
| Base House Total Power |
68.3 |
 |
| Energy House Total Power |
41.7 |
 |
Equipment Energy Use |
|
|
| Base House Space Conditioning Power |
42.1 |
 |
| Energy House Space Conditioning Power |
24.9 |
 |
| Base House Water Heating Power |
8.1 |
 |
| Energy House Water Heating Power |
2.0 |
 |
Indoor Conditions |
Avg |
Min/Max |
| Base House Temp (F) |
73.8 |
73.1/ 74.8 |
| Energy House Temp (F) |
73.9 |
73.3/ 74.7 |
| Base House RH (%) |
42.9 |
40.8/ 46.4 |
| Energy House RH (%) |
45.1 |
43.5/ 48.4 |
Ambient Conditions |
Avg |
Min/Max |
| Outside Temp (F) |
85.4 |
74.1/ 99.4 |
| Outside RH (%) |
51.6 |
29.0/ 77.0 |
|
|
|
|
|